--- title: "EnviroPro®" slug: "enviropro" updated: 2026-07-31T19:37:13Z published: 2026-07-31T19:37:13Z canonical: "docs.verdi.ag/enviropro" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.verdi.ag/llms.txt > Use this file to discover all available pages before exploring further. # EnviroPro® ### Sensor Overview Sample more soil – EnviroPro® sensors are uniquely designed to have a much larger field of influence than other capacitance probes of similar diameter, providing more meaningful measurements of the local soil. Compensated measurements – All EnviroPro® sensor models compensate salinity and moisture measurements for variations in temperature, as well as compensating moisture measurements for salinity variations. Maintenance-free – Each probe is individually calibrated in the factory, so they never need to be re-calibrated in the field. This means life-time sensor to sensor and probe to probe repeatability. 5 year warranty – EnviroPro® is confident in the quality of their products, and you should be too. All EnviroPro® soil probes come with a 5 year warranty to ensure low cost of ownership and peace of mind. ## Key Specifications: | Operating Temperature | -7° to 60° C | | --- | --- | | Accuracy and Precision | Moisture resolution: 0.01% Salinity resolution: 0.001 dS/m Temperature resolution: 0.01 °C Moisture accuracy: +/- 2% @ 0% VWC to 50% VWC (*with respect to dielectric) Useable salinity range: 0 to 6 dS/m* (*Upper limit of non-contact capacitance sensors.) Salinity accuracy: +/- 5% @ 0-4 dS/m at 10%-30% VWC Temperature accuracy: +/- 1 °C @ 25 °C | ## Wiring: - Typically, pre-connected by Verdi prior to delivery. For reference: - If the cable has a connector present, cut off the connector and strip outer insulation to reveal the inner wires - Strip ~10 mm off each of the inner wires - The EnviroPro probe cable will either have 3 or 4 inner wires, connect them to the Dragino following this chart ![](https://cdn.document360.io/21bcacda-1800-45ee-8df3-7d1d6186e001/Images/Documentation/image(264).png?sv=2026-02-06&spr=https&st=2026-11-19T04%3A38%3A15Z&se=2026-11-19T05%3A38%3A15Z&sr=b&sp=r&sig=KTJfc4llmGhC%2F0IyFkeJZlGGe5gxudZ5IAKmQvdjx6E%3D) - Data (blue) goes to SDI-12_data (pin 9) - Power (red) goes to +12V_out (pin 10) - Ground (black) goes to GND (pin 11) After connecting wires, press and hold the power button for 5 seconds to turn the device on. The status LED will blink green 5 times, then blink blue. ### Sensor Technical Specs [Technical Specs](https://enviroprosoilprobes.com/wp-content/uploads/ENTELECHY-EnviroPro_probe-technical-specifications-June2022.pdf) ### Sensor Installation [Installation Manual](https://enviroprosoilprobes.com/wp-content/uploads/2020/03/ENTELECHY_EnviroPro_Installation-Manual_Mar2020.pdf)