--- title: "Flow Meter Device Configuration" slug: "flow-meter-configuration" updated: 2026-01-05T20:45:43Z published: 2026-01-05T20:45:43Z canonical: "docs.verdi.ag/flow-meter-configuration" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.verdi.ag/llms.txt > Use this file to discover all available pages before exploring further. # Flow Meter Device Configuration To configure a Verdi [Block Controller](/v1/docs/block-controller-introduction) that is wired to a flow meter via a [Sensor Adapter](/v1/docs/sensor-adapter) (required for flow meter wiring), follow the procedure: 1. In the [Map View](/v1/docs/map-view), click the [Device Marker](/v1/docs/device-markers) of the Block Controller that is wired to the flow meter. 2. Scroll to the bottom of the [Device Card](/v1/docs/device-card) and click on “Device configuration”. 3. Scroll down to the “Sensor connections” header and click on “S2” to open the “S2 Sensor Settings”. 4. Click on the “Sensor type” drop-down and select your flow meter model or select “Generic Flowmeter (Unknown)“ 5. If you selected “Generic Flowmeter (Unknown)“: Scroll down to the “Sensor parameters” header. Find the K-factor and offset from the datasheet of your flow meter. Enter K-Factor. Note that a unit change of K-factor changes the units for Flowrate. Enter Offset. Note that Offset should have units “pulse/min”. Click “Save settings“. ![](https://cdn.document360.io/21bcacda-1800-45ee-8df3-7d1d6186e001/Images/Documentation/image(245).png?sv=2026-02-06&spr=https&st=2026-11-19T04%3A28%3A11Z&se=2026-11-19T05%3A28%3A11Z&sr=b&sp=r&sig=KSY7YBbsg8X6gXsZSdvNdZVRxBFTfwaWRLNUZh%2BOrbw%3D) The following equations can be used to troubleshoot Generic flow meters: Frequency *(pulse/min)* = Flowrate *(L/min or Gal/min)* ÷ K-factor *(L/pulse or Gal/pulse)* − Offset *(pulse/min)* The equation can be re-arranged: Flowrate *(L/min or Gal/min)* = (Frequency *(pulse/min)* + Offset *(pulse/min)*) * K-factor *(L/pulse or Gal/pulse)*