--- title: "Sensor-Driven Automation" slug: "sensor-driven-automation" updated: 2026-09-25T01:28:51Z published: 2026-09-25T01:28:51Z canonical: "docs.verdi.ag/sensor-driven-automation" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.verdi.ag/llms.txt > Use this file to discover all available pages before exploring further. # Sensor-Driven Automation *This feature is available but in beta.* ## Introduction The Verdi Block Controller and Verdi Micro-Block Controller can open or close a valve based on a sensor wired into that same controller, with a response time as fast as 30 seconds. This enables applications like heat protection, frost protection, pressure switch, flow switch, and soil moisture automation. > [!CAUTION] > Important note > > Sensor-driven automation is currently wired and on-device only. A sensor can only act on the controller it is wired into. It cannot trigger an action on any other device. ## How It Works The controller reads the sensor wired into it, compares the reading to the ***Target*** you set, and opens or closes its own valve. A sensor wired into a controller **can**: - Open or close the valve connected to that controller - Turn a pump on or off, if that controller is a Block Controller driving a pump relay (see [Pump Control](/v1/docs/pump-control)) A sensor wired into a controller **cannot**: - Open or close a valve on another controller - Open or close a group of controllers - Turn on a pump controlled by another controller, including a parent pump controller linked to the zone - Start an irrigation sequence or set across multiple zones To automate several zones, wire a sensor into each zone's controller and enable automation on each one. ## How to Use Before you start, wire the sensor into the Block Controller or Micro-Block Controller whose valve you want to automate. To enable this feature, click the settings icon beside ***Automation - Disabled*** in the [Device Card](/v1/docs/device-card). Select *dutyCycle* in the ***Automation Mode*** dropdown. Select the sensor (e.g., Teros 10 soil moisture) in the ***Sensor*** dropdown. Enter a ***Target*** metric. For soil moisture, this would typically be the volumetric water content value for the onset of stress or field capacity minus plant available water. Select a ***Duty Cycle Period*** in the dropdown. This will determine how frequently the system will check if the sensor is above the ***Target***. Select ***Irrigate Below Threshold*** (green) if the zone should be irrigated when the sensor reads below the ***Target***. Valves will open until the next duty cycle (see ***Duty Cycle Period***). Set the ***Duty Cycle Period*** percentage to 100%. Click ***Save*** to commit the changes. This must be completed on every device intended to operate under sensor-driven automation, and each of those devices needs its own wired sensor. ![](https://cdn.document360.io/21bcacda-1800-45ee-8df3-7d1d6186e001/Images/Documentation/image-1736122111963.png?sv=2026-02-06&spr=https&st=2026-11-19T04%3A38%3A16Z&se=2026-11-19T05%3A38%3A16Z&sr=b&sp=r&sig=zoD97cYBGiMqbSsUIoNATYYBywjS5B8kUuKRK7z%2Bxyw%3D) ## Supported External Sensors The following sensor types are supported when wired directly into the controller: - Single-Depth Soil Moisture - Air Temperature - Water Pressure - Water Flow Wireless sensors and sensors connected to another device cannot trigger automation. This includes the [Sensoterra Single-Depth Soil Moisture Sensor (Wireless)](/v1/docs/sensoterra-soil-moisture-sensors) and sensors connected to an [SDI-12 Telemetry Node](/v1/docs/sdi-12-telemetry-node). Their readings still appear on the dashboard. ## Response Time The sensor can be read every 30 seconds, and the valve will open or close immediately. ## Wireless Sensor-Driven Automation (Roadmap) Wireless, system-wide sensor-driven automation is on the Verdi roadmap. The goal is to let one sensor trigger actions on other devices, for example: - A soil moisture probe starting an irrigation sequence across several valves, or a valve and its pump - A temperature sensor in the middle of a field starting a frost protection sequence across several zones - A pressure transducer in one location turning on a pump and several valves This feature does not have a release date yet. Until it is available, each controller you want to automate needs its own wired sensor. If this capability matters for your operation, contact us to share your use case.